AOD-9604

$45.00

AOD 9604 Peptide supplied as 5mg lyophilised powder, tested by HPLC and mass spectrometry to ≥99% purity. Every vial carries a scannable per-lot certificate of analysis.

For laboratory research use only. Not for human or veterinary consumption.

SKU: CYT-AOD-05 Category:

Description

AOD 9604 Peptide is supplied by Cytera Peptides as a lyophilised powder in 5mg vials, independently tested by HPLC and mass spectrometry to a minimum of 99% purity. Every vial carries a scannable per-lot certificate of analysis, so the material in your hand can be matched to the exact batch it came from.

AOD-9604 is studied in the context of metabolic and energy-regulation research. This listing is intended for qualified researchers and laboratory purchasers.

AOD 9604 Peptide — technical overview

hGH (177-191) fragment analogue. The material ships as a white to off-white lyophilised cake under vacuum seal. Lyophilisation removes water by sublimation, which is what gives the dry powder its long shelf stability compared with material held in solution.

Each production lot is assayed independently rather than by the manufacturer alone. Reversed-phase HPLC establishes purity as a percentage of total peak area, and mass spectrometry confirms that the molecular weight of the principal peak matches the expected structure — purity and identity are two separate questions, and both are answered before a lot is released.

Specifications

Compound AOD-9604
CAS number 221231-10-3
Molecular formula C78H123N23O23S2
Molecular weight 1815.1 g/mol
Available sizes 5mg
Physical form Lyophilised powder
Purity ≥99% (HPLC, area normalisation)
Identity Confirmed by mass spectrometry
Storage — sealed −20 °C, protected from light
Storage — reconstituted 2–8 °C, use within the period stated on the COA
Category Metabolic

Certificate of analysis

Every AOD-9604 vial is printed with a QR code that resolves to the certificate of analysis for that specific lot — not a generic sample document. The COA states the assay result, the method used, the lot number and the release date. You can browse the full COA library without buying anything.

This matters more in this category than in most. Purity claims are trivially easy to assert and difficult for a buyer to verify, which is why we publish per-lot documentation rather than a single certificate reused across every batch.

Reconstitution and handling

AOD-9604 arrives dry and must be reconstituted with bacteriostatic water before any measurement can be made. The resulting concentration depends entirely on how much solvent is added: the same vial can yield very different mg/ml figures. Our free peptide calculator works out concentration, draw volume and insulin-syringe units for any combination.

  • Add solvent slowly against the inside wall of the vial, never directly onto the cake.
  • Swirl gently to dissolve. Do not shake — foaming indicates denaturation.
  • Return reconstituted material to 2–8 °C and avoid repeated freeze–thaw cycles.
  • Keep the vial protected from light at all times.

Bacteriostatic water contains 0.9% benzyl alcohol, which allows a vial to be entered more than once. Sterile water contains no preservative and is single use only. Bacteriostatic water and reconstitution supplies are stocked alongside the catalogue.

Published literature on aod 9604 peptide

Researchers evaluating aod 9604 peptide typically begin with the primary literature. Indexed publications are searchable through PubMed. Cytera does not summarise or interpret findings, and nothing in this listing should be read as a claim about outcomes in any organism.

Frequently asked questions

What purity is this AOD-9604?

Every lot is released at a minimum of 99% purity by reversed-phase HPLC, with identity confirmed by mass spectrometry. The exact figure for your lot is on its COA.

How much bacteriostatic water should be added?

There is no single answer — it sets the concentration. Use the calculator to find a dilution that puts your intended measurement in a readable range on the syringe.

How is it shipped?

Lyophilised powder is stable in transit at ambient temperature. Orders placed before 2pm ET ship the same business day from within the United States.

Can I see the COA before ordering?

Yes. The COA library is public and lot-searchable.

Is this material approved for human use?

No. It is supplied strictly for laboratory research and is not a drug, supplement or medical device. It is not approved for human or veterinary administration.

For laboratory research use only. This product is not a drug, food, supplement, cosmetic or medical device. It is not for human or veterinary consumption, diagnostic, therapeutic or any in-vivo use. Purchase is restricted to qualified researchers and institutions, and the buyer assumes full responsibility for safe and lawful handling.

Reviews

There are no reviews yet.

Be the first to review “AOD-9604”

Your email address will not be published. Required fields are marked *